REMOV CONC (FOUNDATIONS)
|
CY
|
10.000
|
|
|
DRILL SHAFT (TRF SIG POLE) (24 IN)
|
LF
|
54.000
|
|
|
DRILL SHAFT (TRF SIG POLE) (30 IN)
|
LF
|
33.000
|
|
|
DRILL SHAFT (TRF SIG POLE) (36 IN)
|
LF
|
26.000
|
|
|
DRILL SHAFT (TRF SIG POLE) (48 IN)
|
LF
|
22.000
|
|
|
MOBILIZATION (CALLOUT)
|
EA
|
60.000
|
|
|
MOBILIZATION (EMERGENCY)
|
EA
|
10.000
|
|
|
PORTABLE CHANGEABLE MESSAGE SIGN
|
DAY
|
20.000
|
|
|
TMA (STATIONARY)
|
DAY
|
30.000
|
|
|
TMA (MOBILE OPERATION)
|
DAY
|
100.000
|
|
|
BIODEG EROSN CONT LOGS (INSTL) (18")
|
LF
|
50.000
|
|
|
BIODEG EROSN CONT LOGS (REMOVE)
|
LF
|
50.000
|
|
|
CONC SIDEWALKS (4")
|
SY
|
40.000
|
|
|
CONDT (PVC) (SCH 40) (2")
|
LF
|
750.000
|
|
|
CONDT (PVC) (SCH 40) (2") (BORE)
|
LF
|
650.000
|
|
|
CONDT (PVC) (SCH 40) (3")
|
LF
|
400.000
|
|
|
CONDT (PVC) (SCH 40) (3") (BORE)
|
LF
|
600.000
|
|
|
CONDT (PVC) (SCH 40) (4")
|
LF
|
250.000
|
|
|
CONDT (PVC) (SCH 40) (4") (BORE)
|
LF
|
600.000
|
|
|
CONDT (PVC) (SCH 80) (2")
|
LF
|
100.000
|
|
|
CONDT (PVC) (SCH 80) (2") (BORE)
|
LF
|
50.000
|
|
|
CONDT (RM) (1 1/2")
|
LF
|
150.000
|
|
|
CONDT (RM) (2")
|
LF
|
150.000
|
|
|
CONDT (RM) (3")
|
LF
|
150.000
|
|
|
CONDT (RM) (4")
|
LF
|
100.000
|
|
|
CONDUIT (PREPARE)
|
LF
|
500.000
|
|
|
ELEC CONDR (NO.12) BARE
|
LF
|
100.000
|
|
|
ELEC CONDR (NO.12) INSULATED
|
LF
|
200.000
|
|
|
ELEC CONDR (NO.8) BARE
|
LF
|
1,000.000
|
|
|
ELEC CONDR (NO.8) INSULATED
|
LF
|
2,100.000
|
|
|
ELEC CONDR (NO.6) BARE
|
LF
|
1,500.000
|
|
|
ELEC CONDR (NO.6) INSULATED
|
LF
|
800.000
|
|
|
ELEC CONDR (NO.4) BARE
|
LF
|
100.000
|
|
|
ELEC CONDR (NO.4) INSULATED
|
LF
|
200.000
|
|
|
ELEC CONDR (NO.2) BARE
|
LF
|
50.000
|
|
|
ELEC CONDR (NO.2) INSULATED
|
LF
|
100.000
|
|
|
TRAY CABLE (3 CONDR) (12 AWG)
|
LF
|
100.000
|
|
|
TRAY CABLE (3 CONDR) (8 AWG)
|
LF
|
200.000
|
|
|
GROUND BOX TY A (122311)W/APRON
|
EA
|
3.000
|
|
|
GROUND BOX TY C (162911)W/APRON
|
EA
|
3.000
|
|
|
GROUND BOX TY D (162922)W/APRON
|
EA
|
3.000
|
|
|
REMOVE GROUND BOX
|
EA
|
5.000
|
|
|
ZINC-COAT STL WIRE STRAND (3/16")
|
LF
|
3,000.000
|
|
|
ZINC-COAT STL WIRE STRAND (1/4")
|
LF
|
1,500.000
|
|
|
ZINC-COAT STL WIRE STRAND (5/16")
|
LF
|
3,000.000
|
|
|
ZINC-COAT STL WIRE STRAND (3/8")
|
LF
|
2,000.000
|
|
|
REMOVE ELECTRICAL SERVICES
|
EA
|
5.000
|
|
|
ELC SRV TY D 120/240 070(NS)SS(E)GC(O)
|
EA
|
2.000
|
|
|
ELC SRV TY D 120/240 070(NS)SS(E)PS(U)
|
EA
|
2.000
|
|
|
TRF SIG CBL (TY A)(14 AWG)(5 CONDR)
|
LF
|
800.000
|
|
|
TRF SIG CBL (TY A)(14 AWG)(7 CONDR)
|
LF
|
1,500.000
|
|
|
TRF SIG CBL (TY A)(14 AWG)(9 CONDR)
|
LF
|
2,000.000
|
|
|
TRF SIG CBL (TY A)(14 AWG)(12 CONDR)
|
LF
|
500.000
|
|
|
TRF SIG CBL (TY A)(14 AWG)(16 CONDR)
|
LF
|
2,500.000
|
|
|
TRF SIG CBL (TY A)(14 AWG)(20 CONDR)
|
LF
|
3,000.000
|
|
|
TRF SIG CBL (TY C)(12 AWG)(2 CONDR)
|
LF
|
800.000
|
|
|
TRF SIG CBL (TY C)(14 AWG)(2 CONDR)
|
LF
|
2,000.000
|
|
|
VEH LP DETECT (SAWCUT)
|
LF
|
300.000
|
|
|
REMOVAL OF CONDUIT
|
LF
|
100.000
|
|
|
REMOVAL OF CABLES
|
LF
|
8,000.000
|
|
|
REPLACE OF CABLES
|
LF
|
400.000
|
|
|
INSTALL OF CABLES
|
LF
|
5,000.000
|
|
|
REMOVAL OF CABLES BY MESSENGER CABLE
|
LF
|
400.000
|
|
|
REPLACE OF CABLES BY MESSENGER CABLE
|
LF
|
900.000
|
|
|
INSTALL OF CABLES BY MESSENGER CABLE
|
LF
|
900.000
|
|
|
REMOVAL OF SPAN CABLE ASSM
|
LF
|
1,200.000
|
|
|
REPLACE OF SPAN CABLE ASSM
|
LF
|
1,000.000
|
|
|
REPLACE OF ELECTRICAL SERVICE
|
EA
|
2.000
|
|
|
INSTALL OF ELECTRICAL SERVICE
|
EA
|
2.000
|
|
|
REMOVAL OF TIMBER POLES
|
EA
|
3.000
|
|
|
REPLACE OF TIMBER POLES
|
EA
|
3.000
|
|
|
INSTALL OF TIMBER POLES
|
EA
|
5.000
|
|
|
REMOVAL OF SIGNAL HEAD ASSM
|
EA
|
12.000
|
|
|
REPLACE OF SIGNAL HEAD ASSM
|
EA
|
12.000
|
|
|
INSTALL OF SIGNAL HEAD ASSM
|
EA
|
10.000
|
|
|
REMOVAL OF SIGNAL RELATED SIGNS
|
EA
|
10.000
|
|
|
REPLACE OF SIGNAL RELATED SIGNS
|
EA
|
10.000
|
|
|
INSTALL OF SIGNAL RELATED SIGNS
|
EA
|
10.000
|
|
|
REMOVAL OF PEDESTRIAN PUSH BUTTONS
|
EA
|
7.000
|
|
|
REPLACE OF PEDESTRIAN PUSH BUTTONS
|
EA
|
7.000
|
|
|
INSTALL OF PEDESTRIAN PUSH BUTTONS
|
EA
|
7.000
|
|
|
INSTALL OF FND FOR GROUND MNT CABINETS
|
EA
|
2.000
|
|
|
INSTALL OF FND FOR POLE MNT CABINETS
|
EA
|
2.000
|
|
|
REMOVAL OF CONTROL CABINET(GRND MNT)
|
EA
|
2.000
|
|
|
REPLACE OF CONTROL CABINET(GRND MNT)
|
EA
|
2.000
|
|
|
INSTALL OF CONTROL CABINET(GRND MNT)
|
EA
|
2.000
|
|
|
REMOVAL OF CONTROL CABINET(POLE MNT)
|
EA
|
2.000
|
|
|
REPLACE OF CONTROL CABINET(POLE MNT)
|
EA
|
2.000
|
|
|
INSTALL OF CONTROL CABINET(POLE MNT)
|
EA
|
2.000
|
|
|
REMOVAL OF FLASHER CABINET
|
EA
|
2.000
|
|
|
REPLACE OF FLASHER CABINET
|
EA
|
2.000
|
|
|
INSTALL OF FLASHER CABINET
|
EA
|
2.000
|
|
|
REMOVAL OF RDSD FLSH BEACON ASSM
|
EA
|
2.000
|
|
|
REPLACE OF RDSD FLSH BEACON ASSM
|
EA
|
2.000
|
|
|
INSTALL OF RDSD FLSH BEACON ASSM
|
EA
|
2.000
|
|
|
REMOVAL OF SIGNAL POLE ASSM
|
EA
|
2.000
|
|
|
REPLACE OF SIGNAL POLE ASSM
|
EA
|
2.000
|
|
|
INSTALL OF SIGNAL POLE ASSM
|
EA
|
2.000
|
|
|
REMOVAL OF LUMINAIRE HEAD
|
EA
|
5.000
|
|
|
REPLACE OF LUMINAIRE HEAD
|
EA
|
15.000
|
|
|
INSTALL OF LUMINAIRE HEAD
|
EA
|
5.000
|
|
|
REMOVAL OF LUMINAIRE MAST ARMS
|
EA
|
5.000
|
|
|
REPLACE OF LUMINAIRE MAST ARMS
|
EA
|
5.000
|
|
|
INSTALL OF LUMINAIRE MAST ARMS
|
EA
|
5.000
|
|
|
INSTL DOWN GUY W/GUARD
|
EA
|
6.000
|
|
|
REPLACE DOWN GUY W/GUARD
|
EA
|
6.000
|
|
|
INSTL DOWN GUY AND ANCHOR W/GUARD
|
EA
|
8.000
|
|
|
REPLACE DOWN GUY AND ANCHOR W/GUARD
|
EA
|
8.000
|
|
|
INSTL VID IMAGE VEH DET SYS (VIVDS)
|
EA
|
5.000
|
|
|
REPLACE VID IMAGE VEH DET SYS (VIVDS)
|
EA
|
5.000
|
|
|
REMOVE VID IMAGE VEH DET SYS (VIVDS)
|
EA
|
18.000
|
|
|
INSTL PED POLE ASSM
|
EA
|
2.000
|
|
|
REPLACE PED POLE ASSM
|
EA
|
2.000
|
|
|
REMOVE PED POLE ASSM
|
EA
|
2.000
|
|
|
REPLACE LED TRAF SIG LAMP UNIT
|
EA
|
120.000
|
|
|
REPLACE PED SIG LED TRAF SIG LAMP UNIT
|
EA
|
30.000
|
|
|
INSTALL PED SGN LED TRAF SIG AMP UNIT
|
EA
|
15.000
|
|
|
SALVAGE TRAFFIC SIGNAL
|
EA
|
3.000
|
|
|
RELOCATE OF PEDESTRIAN PUSH BUTTON
|
EA
|
9.000
|
|
|
INSTALL SCREW-IN FND
|
EA
|
6.000
|
|
|
REMOVE SCREW-IN FND
|
EA
|
3.000
|
|
|
REPLACE CONTROLLER BREAKAWAY BASE
|
EA
|
3.000
|
|
|
INSTALL BBU SYSTEM
|
EA
|
3.000
|
|
|
REPLACE BBU SYSTEM
|
EA
|
3.000
|
|
|
INSTALL RADAR VEHICLE DETECTION SYSTEM
|
EA
|
20.000
|
|
|
REPLACE RADAR VEHICLE DETECTION SYSTEM
|
EA
|
5.000
|
|
|
REMOVE RADAR VEHICLE DETECTION SYSTEM
|
EA
|
5.000
|
|
|
REPL VEH SIG TUNNEL VISOR (12")
|
EA
|
20.000
|
|
|
VIVDS CABLING
|
LF
|
3,000.000
|
|
|
RVDS (PRESENCE DETECTION ONLY)
|
EA
|
3.000
|
|
|
RVDS (ADVANCE DETECTION ONLY)
|
EA
|
3.000
|
|
|
RVDS (PRESENCE AND ADVANCE DETECTION)
|
EA
|
3.000
|
|
|
GROUND BOX (PREPARE)
|
EA
|
125.000
|
|
|
PREVENTIVE MAINTENANCE
|
EA
|
175.000
|